3 Wire 30VAC Differential Pressure Transducers 100Ω Output Impedance

Product Details

Place of Origin: China

Brand Name: CSPPM

Certification: CE

Model Number: PPM-WCY61-P050A

Payment & Shipping Terms

Minimum Order Quantity: 1 PCS

Packaging Details: Standard export packing, including instructions and certificate

Delivery Time: 5-8 working days

Payment Terms: L/C, T/T, Western Union, MoneyGram

Supply Ability: 1000 pcs per month

Get Best Price
Contact Now
Specifications
Highlight:

100Ω Differential Pressure Transducers

,

30VAC Differential Pressure Transducers

,

30VAC Differential Pressure Detector

Operating:
-18 ~ +65°C
Storage:
-54 ~ +82°C
Electrical Connection:
PG-9 Cable Locking Device
Pressure Fitting:
3/16” O.D.Barbed Brass Pressure Fitting For 1/4” Push-on Tubing
Zero And Span Adjustments:
Accessible Inside Of Case
Operating:
-18 ~ +65°C
Storage:
-54 ~ +82°C
Electrical Connection:
PG-9 Cable Locking Device
Pressure Fitting:
3/16” O.D.Barbed Brass Pressure Fitting For 1/4” Push-on Tubing
Zero And Span Adjustments:
Accessible Inside Of Case
Description
3 Wire 30VAC Differential Pressure Transducers 100Ω Output Impedance

PPM-WCY61-P050A Pharmaceutical Plant Low Differential Pressure Transducer
 
Product Introduction:
It is consisted of stainless steel diaphragm and gilt ceramic fixed electrode. When pressure changes, the space between two electrode pad also changes, which result in the change in capacitance value. And then the unique detective circuit will transfer the change of capacitance value into linear DC signal.
inherit the consistent characteristics of high-precision, rapid-response and low range. Considering the requirement of pharmaceutical plant and clean room for low differential pressure transducer, on-site LCD is developed and accessories with non-dust accumulation surface are added to meet the industrial applying requirement; so it is a desire choice for pharmaceutical plant, clean rooms of electronic factory and no-dust laboratory. low differential pressure transducer can measures pressure difference or gauge pressure (static pressure) and can choose the output signal in 4-20mA, 0-5VDC or 0-10VDC. transducer has conducted temperature compensation with an exciting voltage of 24VDC and can choose 24VAC as power supply for voltage signal product. The minimum measurement of Model 261C range is at 0 ~ 25Pa with an accuracy of ±1%FS at room temperature; The unit are temperature compensated to ±0.06%FS/°C thermal error over the temperature range +5 to +65°C.
 
Applications :
Pharmaceutical Plant
Clean Room
Bio-Safety Labs
Infectious Disease Room
Stairwell Fire and Smoke Protection
 
Technical Parameters :

Parameter

Accuracy RSS* (constant temperature)

Standard

±1.0%FS

Option

±0.4%FS

Option

±0.25%FS

Non-Linearity, BFSL±0.98%FS±0.33%FS±0.20%FS
Non-Repeatability±0.05%FS±0.05%FS±0.05%FS
Hysteresis±0.1%FS±0.1%FS±0.1%FS
Compensation range-5 ~ +65°C (no LCD display)
Zero/ Span shift<0.06%FS/°C
Max. linear pressure70KPa
OverpressureUp to 70KPa in positive or negative direction
Warm up drif±0.1% FS

 

Error caused by installing position

(the nominal position in factory is in vertical position)

RangeZero Drift (%FS/G)
0-25Pa2.1
0-250Pa0.22
0-1250Pa0.14
0-7500Pa0.06

 

* RSS of non-linear, hysteresis and non-repeatability

 

 
Environmental and Physical Data

Operating-18 ~ +65°C
Storage-54 ~ +82°C
Electrical connectionPG-9 cable locking device
Pressure Fitting

3/16” O.D.Barbed Brass pressure fitting for

1/4” push-on tubing

Zero and Span adjustmentsAccessible Inside of Case
Pressure mediumAir or similar non-conducting gas
EnclosureCast aluminum
Weight347.5g
Mountingφ3mm bolt or countersunk head bolt (option)

 
Electrical Data (Voltage)

Circuit3-Wire (Com, Exc, Out)
Exciting

9 ~ 30VAC/12 ~ 42VDC (0 ~ 5VDC output);

12 ~ 30VAC/13 ~ 42VDC (0 ~ 10VDC output)

Output*0-5VDC/0-10VDC**
Bidirectional Output at Zero2.5VDC(0-5VDC) / 5VDC(0-10VDC)
Output Impedance100Ω

*Calibrated into a 50KΩ load, operable into a 5KΩor greater.
** Zero output factory set to within ±50mV (± 25mV for option accuracy)
** Span(Full scale) output factory set to within ±50mV (± 25mV for option accuracy)
 
Electrical Data (Current)

Circuit2-Wire Protected from Miswiring
Full scale output*20mA±0.16mA
Zero point output*4mA±0.16mA
Bidirectional Output at Zero12mA
External load0-800Ω
Min. supply voltage9+0.02×(Resistance of receiver plus line)VDC
Max. supply voltage30+0.004 × (Resistance of receiver plus line)VDC

* Calibrated with a 24VDC loop supply voltage and a 250 ohm load
 
Definition of wiring:
3 Wire 30VAC Differential Pressure Transducers 100Ω Output Impedance 0
Dimensions in mm :
3 Wire 30VAC Differential Pressure Transducers 100Ω Output Impedance 1