Send Message
Home ProductsDigital Process Indicator

Intelligent 10V AC Circuit Check Measure Alarm Instrument Accuracy 0.2% FS

Certification
China Changsha Taihe Electronic Equipment Co. certification
China Changsha Taihe Electronic Equipment Co. certification
Customer Reviews
I ordered the product and used it, it was good and I would recommend dealing with the company.

—— F**************r

Fully satisfied, fast charging, courteous and good handling. Worth buying from them, and also very good prices. And also the seller is keen on product safety and prompt response .

—— D**********E

What was ordered is what was delivered. Highly recommend them on matters of digital pressure sensors

—— J**********a

I'm Online Chat Now

Intelligent 10V AC Circuit Check Measure Alarm Instrument Accuracy 0.2% FS

Intelligent 10V AC Circuit Check Measure Alarm Instrument Accuracy 0.2% FS
Intelligent 10V AC Circuit Check Measure Alarm Instrument Accuracy 0.2% FS Intelligent 10V AC Circuit Check Measure Alarm Instrument Accuracy 0.2% FS

Large Image :  Intelligent 10V AC Circuit Check Measure Alarm Instrument Accuracy 0.2% FS

Product Details:
Place of Origin: China
Brand Name: CSPPM
Certification: CE
Model Number: PPM-TC1CL
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Standard package

Intelligent 10V AC Circuit Check Measure Alarm Instrument Accuracy 0.2% FS

Description
Accuracy: 0.2% FS Measurement Speed: 10 Times Per Second
Face-plate: 2-bit LED(Channel Number)+ 4-bit LED(Measured Value) Alarm: Standard 2 Points Can Be Extended To 4 Points. 250V AC/3A Resistive Load
Power Supply: 100-240V AC 50/60 Hz Or 10-24V AC 50/60 Hz;10-24V DC Printing Function: Fission Printing Or Integrative Printing
High Light:

10V AC Circuit Check Measure Alarm Instrument

,

0.2% FS Circuit Check Measure Alarm Instrument

,

10V AC Circuit Check Instrument

Intelligent Circuit Check Measure Alarm Instrument

 

PPM-TC1CL Intelligent Circuit Check & Measure Alarm Instrument applies to checking, measurement and alarm of 5~80 points process quantity. It is adapted to signals of thermocouple, RTD, DC current, DC voltage sensors and re-transmitters.

 

 

 

1. Basic intrinsic error is less than 0.2%, indication range is -1999~9999.

2. The signal type, range, alarm value of each channel can be set separately.

3. Digital filtering time coefficient of each channel, which can improve anti-interference ability, can be set separately.

4. Zero and full scale correction, which can effectively reduce sensor error to improve measuring accuracy of the system, can be set separately.

5. Useless channels can be shut at will.

6. The 2nd grade parameter. The 2nd grade parameter is controlled by security code to prevent misoperation. Parameter copying function, which can greatly reduce workload of parameter setting, is also available.

7. Unique and practical alarm function, which is the connection to the LCU multiple controlling unit, can actualize alarm output of every channel.

8. Manual, timing, alarm start printing.

9. High-speed, high-efficiency communication interface can greatly reduce communication time.

 

  Code Description
PPM-TC1CL- 8~80 channel;0.2% accuracy;measurement speed:10 times per second
Dimension A 160×84×142 tapping:152×76
B 84×160×142 tapping:76×152
C 160×160×182 tapping:152×152
D1 318×104×300 desktop type
D2 318×104×300 tray use tapping:312×96
Faceplate   2-bit LED(Channel number)+ 4-bit LED(Measured value)

 

Channels(Channels of A/B type ≤32;Channels of C,D1,D2≤80)

08 8 channels
16 16 channels
24 24 channels
32 32 channels
40 40 channels
48 48 channels
56 56 channels
64 64 channels
72 72 channels
80 80 channels
Input Signal R All channels are RTD,Pt100,Cu100,Cu50,BA1,BA2,G53
E All channels are Thermocouple,K,S,R,B,N,E,J,T
B

All channels are DC current signals((4-20)mA/(0-10)mA/(0-20)mA)Or DC voltage signals((0-5)V/(1-5)V).

Notification of current or voltage signal channel is needed on order.

X Input signals are RTD and Thermocouple mix
L Input signals are RTD, thermocouple, 4mA~20mA,0mA~10mA,1V~5V,0V~5V mix. Notification of current or voltage signal channel is needed on order.
Alarm   Standard 2 points can be extended to 4 points. 250V AC/3A Resistive load

Communication Interface

(Communication speed:2400,4800,9600,19200)

(Communication address:0-99)

S1 TC ASCII RS232
S2 TC ASCII RS485
M1 Modbus-RTU RS232
M2 Modbus-RTU RS485

Printing Function

(Only for S1,S2 type)

P1 Fission Printing
P2 Integrative Printing
Power supply V0 100-240V AC 50/60 Hz
V1 10-24V AC 50/60 Hz;10-24V DC

Contact Details
Changsha Taihe Electronic Equipment Co.

Contact Person: Mr. William

Send your inquiry directly to us (0 / 3000)

Other Products